Directed Electronics 50.7X Specifications

Browse online or download Specifications for Car alarm Directed Electronics 50.7X. Directed Electronics 50.7X Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SPECIFICATIONS
ELECTRICAL
CURRENT CONSUMPTION
VOLTAGE REQUIREMENTS
ALARM CONTACTS
TAMPER CONTACTS
ACOUSTIC SENSOR
PHYSICAL
SIZE
WEIGHT
GLASS
TYPES
SIZES
87 x 50.7 x 28.6 mm (3.4 x 2.0 x 1.1 in.)
63.70g (2.25
OZ.)
Intended to be connected to a UL control panel capable of providing 4
hours of standby power. Test annually.
Specifications are subject to change without prior notice. Should
any questions arise please contact your nearest distributor.
ROKONET LIMITED WARRANTY
Rokonet Electronics, Ltd. and its subsidiaries and affiliates ("Seller")
warrants its products to be free from defects in materials and workmanship
under normal use for 18 months from the date of production. Because
Seller does not install or connect the product and because the product may
be used in conjunction with products not manufactured by Seller, Seller
cannot guarantee the performance of the security system which uses this
product. Seller's obligation and liability under this warranty is expressly
limited to repairing or replacing, at Seller's option, within a reasonable time
after the date of delivery, any product not meeting the specifications.
Seller makes no other warranty, expressed or implied, and makes no
warranty of merchantability or of fitness for any particular purpose.
In no case shall seller be liable for any consequential of incidental damages
for breach of this or any other warranty, expressed or implied, or upon any
other basis of liability whatsoever.
Seller's obligation under this warranty shall not include any transportation
charges or costs of installation or any liability for direct, indirect, or
consequential damages or delay.
Seller does not represent that its products may not be compromised or
circumvented; that the product will prevent any personal injury or property
loss by burglary, robbery, fire or otherwise; or that the product will in all
cases provide adequate warning or protection. Buyer understands that a
properly installed and maintained alarm may only reduce the risk of burglary,
robbery of fire without warning, but it is not insurance or a guarantee that
such will not occur or that there will be no personal injury or property loss
as a result.
Consequently seller shall have no liability for any personal injury, property
damage or other loss based on a claim that the product fails to give
warning. However, if seller is held liable, whether directly or indirectly, for
any loss or damage arising under this limited warranty or otherwise,
regardless of cause of origin, seller's maximum liability shall not in any
case exceed the purchase price of the product, which shall be the complete
and exclusive remedy against seller.
No employee or representative of Seller is authorized to change this
warranty in any way or grant any other warranty.
WARNING: This product should be tested at least once a week.
ROKONET ELECTRONICS LTD.
14 HACHOMA ST.
75655 RISHON LETZION. ISRAEL.
TEL: (972) 3 961 6555 FAX: (972) 3 961 6584
TEL: (1) 800 344 2025
TEL: (44) 1527 576 765
TEL: (33) 1 4367 0077
TEL: (49) 821 742 660
TEL: (39) 35 683013
5 INS 60 B
ROKONET USA:
ROKONET UK:
ROKONET FRANCE:
ROKONET GERMANY:
ROKONET ITALY:
FAX: (1) 914 592 1271
FAX: (44) 1527 576 816
FAX: (33) 1 4367 0099
FAX: (49) 821 742 499
FAX: (39) 35 683013
© 1998 Rokonet Electronics Ltd
20mA at 12V (24mA max)
9.3 - 16 VDC
NC, 24 VDC, 50mA
NC, 24 VDC, 0.5A
Omni Directional Microphone
Plate, laminated, wired & tempered.
30 x 30cm (12" x 12") minimum, except
for 9m / 30ft RG-61 with 50 x 50cm
(20" x 20")
0˚C to 55˚C (32˚F to 131˚F)
-20˚C to 60˚C (-4˚F to 140˚F)
ENVIRONMENTAL
OPERATING TEMPERATURE
STORAGE TEMPERATURE
RG-61U
Rev.B
FOR MORE INFORMATION SEE TIN-2
There are three types of indication in normal mode:
Active Supervision: Any loud sounds such as clapping, whistling or key-
jingling should produce a flash of the VITRON's LED.
This verifies that the VITRON is active. The alarm
relay is not opened.
Passive Supervision: The Vitron continuously monitors its audio channel.
If no sounds are registered for more than 24 hours
the LED will flash rapidly. This indication will
persist until a sound is registered. The alarm relay
is not opened.
Alarm: On detection of framed glass being broken from
outside the LED will light continuously for 3 seconds
and the alarm relay will open.
STEP 7 NORMAL OPERATION
Note: all tests should be conducted under worst-case conditions. All
sounds should be generated behind curtains or blinds.
Observe the VITRON and note any disturbances:
STEP 6 MEMORY INDICATION
To use the MEMORY option - remove the Jumper. The LED is
latched on the first alarm.
The LED is reset by temporarily removing the power from the detector
(using a Switched 12V line from the control panel).
MEM
OFF
Wire the cable to the Terminal Block as follows (see fig 5):
12 VDC
ALARM
TAMPER
EOL
: Power supply inputs
: Normally-Closed relay outputs
: Normally-Closed Tamper switch outputs
: End-of-Line resistor connection
STEP 4 TERMINAL WIRING
NOTE: The VITRON will return to NORMAL mode after two minutes.
Setting the "CODE" switch and pressing the "Manual" button at any
time will initiate another two minutes of Full Remote Test Mode.
LED Indication
Blinks once every 2 sec.
Rapid Flashes
Continuously ON for 3 sec.
Disturbance Possible Cause
NONE
YES
YES
* * *
Low frequency sound
High frequency sound
Fig 5: VITRON PCB - General View
Testing should be performed using the RG65 VITRON tester which has
been specially designed and calibrated to give accurate range test results.
Set lower selector switch on RG65 to CODE setting. Press operating button
on tester to put unit into test mode. VITRON LED will blink every 2 seconds.
HIGH FREQUENCY (AUDIO) TEST:
Position the Glass Break Simulator at the farthest point on the protected
glass and face it into the room. Set lower selector to GLASS setting and
upper to type of glass to be simulated. Generate glass-break sound by
pressing operating button. Verify that VITRON LED comes on for 3 seconds
and ALARM relay is activated.
LOW FREQUENCY TEST:
Tap the window gently. (Caution: breaking glass may cause injury).
Verify that the VITRON produces several rapid flashes of its LED in
conjunction with each tap. The ALARM relay is not activated in this case.
STEP 5 TESTING
ENVIRONMENTAL TEST
Operate all devices in the protected region that may interfere with the
detector, including air conditioners, fans, radios etc.
If disturbances occur, re - position the unit and re-test.
Turn all noise generating equipment off and wait until unit returns to
NORMAL mode.
If RG65 tester is not available test mode can be initiated by opening front
cover and pressing the test button. The VITRON LED will blink every 2
seconds. Replace front cover. VITRON will automatically return to normal
operation after 5 minutes. Pressing the button again during the test mode will
immediately return unit to normal mode. Functional test can now be performed
using another tester.
NOTE: Any test performed using testers other than RG65 will not give
accurate range results.
6/98
T
H
I
S
P
A
P
E
R
C
A
N
B
E
R
E
C
Y
C
L
E
D
RG-60 & RG-61 models for up to 4.5m or 9m ranges
Suitable for most common types of plate, tempered, laminated and wired
glass:
Minimum size for all types of glass: 30cm x 30cm (12'' x 12'')
Thickness: Plate 3.2 mm - 6.4mm (1/8'' - 1/4'')
Tempered,
Laminated, 6.4 mm (1/4'')
Wired
GENERAL DESCRIPTION
The VITRON is an advanced microprocessor based Acoustic Glass Break
detector. Using advanced glass-breaking pattern analysis of both low
frequency "flex" & high frequency "shatter" channels it will detect the
breaking of most common types of framed glass panes while ignoring false
Table 1: VITRON range of coverage
3.2 - 6.4mm
(1/8''-1/4'')
Thickness
Angle (degrees)
0
15
30
45
60
75
90
Percent of max range
100
96
87
70
50
26
0
MAIN FEATURES
VITRON range of coverage depends on (a) the type of glass (see Table 1)
(b) the angle between VITRON and glass (see Fig 1)
STEP 1 RANGE OF COVERAGE
INSTALLATION PROCEDURE
Type of
Glass
Plate Tempered, Laminated, Wired
Model
Size Max.
Range
Minimum
30x30cm
(12''x12'')
Size Thickness Max.
Range
4.5m
(15ft)
Minimum
30x30cm
(12''x12'')
6.4mm
(1/4'')
3m
(10ft)
RG60
3.2 - 6.4mm
(1/8''-1/4'')
Greater
than
30x30cm
(12''x12'')
9m
(30ft)
Minimum
30x30cm
(12''x12'')
6.4mm
(1/4'')
6m
(20ft)
RG61
Minimum
30x30cm
(12''x12'')
6m
(20ft)
Fig 1: Percentage of Maximum Range as function of angle between Vitron
and glass
Verify that the distance between the VITRON and the furthest point on
the protected glass does not exceed the maximum specified range
taking into account the reduced range due to angle (see Fig 2)
Fig 2:Angle between VITRON and glass
Other factors affecting range:
There should be no obstructions between the VITRON and the protected
glass:
Curtains and blinds may reduce the effective range
Sound absorbing materials in the protected area may reduce the range
ANGLE
VITRON
WINDOW
SIDE VIEW
No adjustments necessary - each unit fully calibrated at factory
Will not alarm if glass pane broken from inside or glass dropped on floor.
Active and passive microphone supervision - verifies unit is working
Full remote test using RG-65 Glass Break Simulator - no need to open
unit
RA66 optional ceiling/wall mount bracket available for optimal mounting
and performance.
Ceiling Mounted
(for optimal results
VITRON is centered
and directed towards
protected glass using
RA-66 Bracket).
Opposite Wall -
Mounted
(For optimal results
VITRON is centered
opposite glass)
Side wall - mounted
(not recommended as
VITRON is not opposite
glass - see range versus
angle diagram.
Test carefully at both
ends of glass using RG-
65 Tester)
For optimal results the VITRON should be mounted as nearly opposite
the glass area to be protected, as shown in Fig 3 below:
STEP 2 MOUNTING LOCATION
Fig 3: VITRON Mounting Options
Open the cover using a flat screwdriver.
STEP 3 MOUNTING
Open the required mounting and cable holes (see Fig 4). The PCB does not
need to be removed unless corner mounting or optional mounting bracket
(RA66) are used.
Fig 4: VITRON Mounting and Cable Holes
Insert the cable through the cable hole and mount the rear cover in its final
location. Seal the remaining holes with sealant.
Snap back the PCB (if removed).
Corner Mounted
(choose corner
opposite glass
to be protected).
VITRON VITRON
VITRON
VITRON
VITRON
VITRON VITRON
VITRON
VITRON
Notes: a) Do not mount VITRON on same wall as protected glass
b) Avoid installing the VITRON near sources of loud noises
or vibrations (air conditioners, fans, compressors, stereos, etc)
75˚
60˚
45˚
30˚
15˚
0˚
VITRON
Mounting
Hole
Holding
Tab
Terminal
Block
Microphone
Alarme
Relay
Holding
Tab
Test
Bouton
Memory Jumper
Screw Hole
Tamper Switch
Terminal
Block
Mounting
Hole
Page view 0
1

Summary of Contents

Page 1 - INSTALLATION PROCEDURE

SPECIFICATIONSELECTRICALCURRENT CONSUMPTIONVOLTAGE REQUIREMENTSALARM CONTACTSTAMPER CONTACTSACOUSTIC SENSORPHYSICALSIZEWEIGHTGLASSTYPESSIZES87 x 50.7

Comments to this Manuals

No comments